CXIS-2517 Product Specifications



Standard Features

Sensitivity: 42 AWG
Resolution: 0.04" (1mm) both vertical and horizontal
Penetration: 1.18" (30mm) steel guaranteed, 1.22" (31mm) typical
Contrast Sensitivity: minimum 24 levels, 4096 gray level
Image Display: Color, Organic, inorganic, B&W, Reverse Monochrome, Pseudo Color
Video Display: 17" LCD Flat-Panel Montiors (2)
Dose: 0.1mR (typical per inspection)
Tunnel Opening: 25.6" (650mm) wide X 17.7" (450mm) high
Conveyor Speed: 0.23m per second (45' per minute)
Power Requirements:

110-120 VAC, 50-60 Hz, 15 Amps max
220-240 VAC, 50-60 Hz, 10 Amps max

Atomic Number Measurement accuracy within 0.5 counts
Density Threat Alert: Programmable Levels
UPS: 2 Minute Backup (after power failure)
Automatic Image Archiving: Up to 50,000 images in a rotating buffer
Manual Save: Windows Format Images
Print Image: User-provided printer (Windows)


X-Ray Generator

Voltage: 160 kVp
Tube Current: 0.7 mA
Cooling: Sealed Oil Bath
Duty Cycle: 100%
Beam Direction: Upward Vertically


Optional Accessories

Entry/Exit Rollers Exit Table
Threat Image Projection 4-Level Security Access
Screener Assist Threat Detection Screener Training Program
Advance Image Archiving (100,000 images) Remote Operator Workstation
Network Supervisor Station Dual 17" LCD Flat-Panel Monitor
High Speed Conveyors 180 kVp X-Ray Generator


X-Ray Detector

1024 Photodiodes in an L-shape Configuration


Physical Specifications

Weight: Approximately 660 lbs. (300 kg)
Shipping Weight: Approximately 770 lbs. (350 kg)


Processor

At a Minimum: Intel Pentium 4 Processor, 2.8 GHz Dual Core, 512 MB Ram, 80GB HDD, 256 MB VGA Dual-DVI, UPS


Design Policy

American Innovations, Inc. pursues & reserves the right to change specifications at any time without notice in the course of continuous development. Any such changes are implemented to maintain or improve the products offered. Equipment may differ in a small detail from the description given.


Health & Safety

Complies with published international health and Safety standards including the U.S. F.D.A. Center for Devices and Radiation Health standards for cabinet x-ray devices (Federal Standard 21-CFR 1020.40). Typical radiation leakage is less than 0.1mR/hr. That is considerably less than the maximum allowed rate of 0.5mR/hr. permitted by Federal law. Film safety is guaranteed for high speed films up to ISO 1600.




For more information, contact:

American Innovations, Inc.
383 West Route 59
Spring Valley, NY 10977

(845) 371-3333
www.mailroomsecurity.com